  Datasheet File OCR Text:
  series am e30 - maz 30 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. f 1 of 3 north america only features: models single output model input voltage (vac/hz) input voltage (vdc ) output voltage (v) output current max (a) efficiency (%) ame30 - 3.3smaz 90 - 264/47 - 440 120 - 370 3.3 6 80 ame30 - 5smaz 90 - 264/47 - 440 120 - 370 5 6 83 ame30 - 12smaz 90 - 264/47 - 44 0 120 - 370 12 2.5 85 ame30 - 15smaz 90 - 264/47 - 440 120 - 370 15 2 85 ame30 - 24smaz 90 - 264/47 - 440 120 - 370 24 1.25 84 models dual output model input voltage ( vac/hz) input voltage (vdc) output voltage (v) output current max (a) efficiency (%) ame30 - 5dmaz 90 - 26 4/47 - 440 120 - 370 5 3 81 ame30 - 12dmaz 90 - 264/47 - 440 120 - 370 12 1.25 84 ame30 - 15dmaz 90 - 264/47 - 440 120 - 370 15 1 83 ame30 - 24dmaz 90 - 26 4 /47 - 440 120 - 370 24 0.625 82 note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. i nput specifications parameters conditions typical maximum units current 1 15 vac 740 ma 2 30 vac 410 ma inrush current <2ms 115 vac 25 a 230 vac 50 a leakage current 150 a external fuse recommended slow blow type 3.15 a input dissipation no load; 115vac <0.5 w no load; 264vac <0.8 start - up time 117 ms output specifications parameters conditions typical maximum units voltage accuracy 2 % line regulation (ll - hl) 0.5 % load regulation 0 - 100% load single 1 % 0 - 100% load dual 2 cross regulation 25% load - 1 st out, 100% load C 2 nd out 5 % maximum capacitive load depending of the model 470 - 23 000 f transient response devi ation 25% load step 2 % of vout ripple & noise* 20mhz bandwidth 50 mv p - p hold - up time (min) 115vac 29 ms minimum load current 0 % of max *ripple & noise measured with 0. 1f m/c and 1f e/c ? 4000vac i/o isolation ? energy star compliant ? medical switching power modules for pcb mounting ? rohs compliant ? operating temperature: - 40 to +85c ? low ripple and noise ? universal i nput: 90 - 264 vac, 47 - 440hz , or 120 - 370vdc ? ce, cul us approvals cb
series am e30 - maz 30 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. f 2 of 3 north america only isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 4000 vac isolation resistance >1000 m general specifications parameters conditions typical maximum units switching frequency 47 khz over current protection auto recovery 110 140 % over voltage protection zener diode clamp 110 % short circuit protection hiccup mode, indefinite short circuit restart auto recovery operating temperature with derating above 55oc - 40 - +85 o c maximu m case temperature 100 o c storage temperature - 40 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity non condensing 95 % rh case material plastic resin + fiberglass (flammability to ul 94v - 0) weight 300 g dimen sions (l x h x w) 3.56 x 2.48 x 1.18 inches 90.5 x 63 x 30 mm mtbf > 800 000 hrs (mil - hdbk - 217f, t=+25 o c) environment approval test parameters conditions shock wave form half sine wave acceleration amplitude 5gn bump duration 30 ms conv erter operation before and after test, body mounted (on chassis) number of bumps 18 (3 in each direction for every axis) vibration test mode sweep sine, 10 - 100hz, speed 0.05hz/s displacement 1 mm acceleration 3g, 3 loops 30min one cycle, 3h total, e very axis tested converter operation before and after test, body mounted (on chassis) safety specifications parameters agency approvals culus, ce , cb standards medical electrical equipment iec \ en \ ul 60601 - 1 , csa - c22.2 no. 601.1 - m90 information tec hnology equipment en 60950 - 1:2006+a11:2009 emi - conducted and radiated emission en550 11 , class b harmonic current emissions iec/en 61000 - 3 - 2, (en60555 - 2) voltage fluctuations and flicker iec/en 61000 - 3 - 3, (en60555 - 3) electrostatic discharge immuni ty iec 61000 - 4 - 2 rf, electromagnetic field immunity iec 61000 - 4 - 3 electrical fast transient/burst immunity iec 61000 - 4 - 4 surge immunity iec 61000 - 4 - 5 rf, conducted disturbance immunity iec 61000 - 4 - 6 power frequency magnetic field immunity iec 610 00 - 4 - 8 voltage dips, short interruptions immunity iec 61000 - 4 - 11
series am e30 - maz 30 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. f 3 of 3 north america only pin out specifications pin single dual 1 ac input ( n ) ac input ( n ) 2 ac input ( l ) ac input ( l ) 3 +v output +v output 4 - v output common 5 n. c. - v output dimensions top view 1 2 3 4 5 4.60 (0.18) 10.00 (0.40) 1.30 (0.05) 27.94 (1.10) 30.00 (1.18) dimensions mm (inch) case tolerance 0.50 (0.02) pin diameter 1.30 0.05 (0.05 0.002) pin pitch tolerance 0.35 (0.014) 63.00 (2.48) 90.50 (3.56) 55.88 (2.20) 4.60 (0.18) 3.56 (0.14) 27.94 (1.10) side view 5? 1.30 (? 0.05) div: 10.00 (0.40) 3.56 (0.14) 81.30 (3.20) 3.56 (0.14) 3.56 (0.14) derating - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area o u t p u t po w e r (% ) 85 ambient temperature o c free air convection 55 o c note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to w ww.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all speci fications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and che micals at the time of publishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardo us environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AME30-12DMAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X